Anyway P series current sensors offer high precision, ultra stable DC and AC current measurement from 100 A to 25 KA.
● Current output and voltage output Version
● Current Range: 100 A – 250000 KA
● Up to 2 ppm linearity error
● 10 to 20 ppm accuracy (Current output)
● Ultra temperature coefficient:0.1 ppm/k
● Single coil, and RackMount mechanical alternative
Anyway P series current sensors offer new and innovation zero-flux-gate technologies that allow non-instructive, high precision and ultra stable DC and AC current measurement. it contains PI and PU two sub-series as following:
PI series: with current output, and the standard versions offer single coil structure when ≤ 1000 A; and Rack mount mechanical versions for ≥ 1000 A.
PU series: which stand for voltage output versions with RackMount mechanical structure.
The PI and PU series DCCT could be widely used to variety applications and industries, such as MRI gradient amplifier, Accelerator of high energy, Magnet power suppliers, Medical cancer treatment system, Military power suppliers, Precision DC current calibration, and photo-lithography. All the off-the-shelf models you may find from the following list:
Products | Current | Ratio | Accuracy | Linearity | Power Supply | ID(mm) |
PI-100 | ±100A | 500:1 | 20ppm | 2ppm | ±12~±15V | 28 |
PI-200 | ±200A | 1000:1 | 10ppm | 2ppm | ±12~±15V | 28 |
PI-400 | ±400A | 1000:1 | 10ppm | 2ppm | ±15V | 28 |
PI-600 | ±600A | 1000:1 | 10ppm | 2ppm | ±15V | 28 |
PI-800 | ±800A | 1500:1 | 10ppm | 2ppm | ±18~±24V | 28 |
PI-1000 | ±1000A | 2000:1 | 10ppm | 2ppm | ±18~±24V | 28 |
PI-1000RM | ±1000A | 1000:1 | 10ppm | 2ppm | 90~260VAC | 60 |
PI-2000RM | ±2000A | 2000:1 | 10ppm | 2ppm | 90~260VAC | 60 90 |
PI-3000RM | ±3000A | 3000:1 | 10ppm | 2ppm | 90~260VAC | 90 120 |
PI-4000RM | ±4000A | 4000:1 | 10ppm | 2ppm | 90~260VAC | 90 120 |
PI-5000RM | ±5000A | 5000:1 | 10ppm | 2ppm | 90~260VAC | 90 120 200 |
PI-6000RM | ±6000A | 5000:1 | 10ppm | 2ppm | 90~260VAC | 90 120 200 |
PI-6000RM | ±6000A | 5000:1 | 10ppm | 2ppm | 90~260VAC | 90 120 200 |
PI-8000RM | ±8000A | 8000:1, (5000:1) |
10ppm | 2ppm | 90~260VAC | 120 160 200 |
PI-10000RM | ±10000A | 8000:1, (5000:1) |
10ppm | 2ppm | 90~260VAC | 120 160 200 |
PI-15000RM | ±15000A | 8000:1, (5000:1) |
10ppm | 2ppm | 90~260VAC | 160 200 |
PI-25000RM | ±25000A | 8000:1, (6400:1) |
10ppm | 2ppm | 90~260VAC | 200 |
Anyway PI series standard DCCT would covers from 100A to 25 KA with current output, and which we recommend RackMount mechanical structure to achieve high stability when the rated primary current beyond 1000 A.
Products | Current | Ratio | Accuracy | Linearity | Power Supply | ID(mm) |
PU-1000RM | ±1000A | 1000A:5V | 100 | 20 | 90~260VAC | 60 |
PU-2000RM | ±2000A | 2000A:5V | 100 | 20 | 90~260VAC | 60 90 |
PU-3000RM | ±3000A | 3000A:5V | 100 | 20 | 90~260VAC | 90 |
PU-4000RM | ±4000A | 4000A:5V | 100 | 20 | 90~260VAC | 90 |
PU-5000RM | ±5000A | 5000A:5V | 100 | 20 | 90~260VAC | 90 |
PU-6000RM | ±6000A | 6000A:5V | 100 | 20 | 90~260VAC | 90 |
PU-8000RM | ±8000A | 8000A:5V | 100 | 20 | 90~260VAC | 120 |
PU-10000RM | ±10000A | 10000A:5V | 100 | 20 | 90~260VAC | 120 |
Please fell free to contact us once meeting others custom requirement,which is available to us if key specifications within given standard range.